{"product_id":"mpx5010dp-differential-pressure-sensor","title":"MPX5010DP 0-10kPa Differential Pressure Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMPX5010DP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a low-pressure differential sensor designed for measuring pressure differences from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0 to 10kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It provides a calibrated analog voltage output, operates from a nominal 5V supply, and features dual pressure ports for air-pressure sensing, monitoring, and embedded control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMPX5010DP 0-10kPa Differential \u003ca href=\"\/collections\/pressure-sensors\" title=\"pressure sensors\"\u003ePressure Sensor\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for accurate measurement of small pressure differences in air-based systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe sensor uses two pressure ports, allowing the pressure applied to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eP1 and P2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to be compared and converted into an analog output voltage. Its integrated signal conditioning provides an amplified, calibrated, and temperature-compensated output, reducing the amount of external analog circuitry required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe MPX5010DP covers a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0 to 10kPa differential pressure range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is well suited to low-pressure air measurement, airflow monitoring, filter monitoring, pneumatic systems, instrumentation, and embedded electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith a nominal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5V supply\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and analog voltage output, the sensor can be interfaced with microcontrollers and development platforms that provide a suitable ADC input. Appropriate voltage limits and ADC compatibility should always be checked before connecting the output directly to a controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMPX5010DP differential pressure sensor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e0 to 10kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e pressure range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDual pressure ports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalog voltage output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternally amplified output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory calibrated sensor architecture\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature-compensated output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNominal 5V operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eApproximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e450mV\/kPa sensitivity\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for low-pressure air measurement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThrough-hole 6-terminal package\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for embedded control and instrumentation projects\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan lang=\"EN-US\"\u003e5.0% Maximum Error over 0\u003c\/span\u003e \u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003e°\u003c\/span\u003e\u003c\/strong\u003e \u003cspan lang=\"EN-US\"\u003eto 85\u003c\/span\u003e \u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003e°\u003c\/span\u003e\u003c\/strong\u003e \u003cspan lang=\"EN-US\"\u003eC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan lang=\"EN-US\"\u003eDurable Epoxy Unibody and Thermoplastic (PPS) Surface Mount Package\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan lang=\"EN-US\"\u003eTemperature Compensated over -40\u003c\/span\u003e \u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003e°\u003c\/span\u003e\u003c\/strong\u003e \u003cspan lang=\"EN-US\"\u003eto +125\u003c\/span\u003e \u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003e°\u003c\/span\u003e\u003c\/strong\u003e \u003cspan lang=\"EN-US\"\u003eC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan lang=\"EN-US\"\u003ePatented Silicon Shear Stress-Strain Gauge\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMPX5010DP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDifferential Pressure Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 10kPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDifferential\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Supply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.75V to 5.25V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Output at 0kPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.2V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Output at 10kPa\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 4.7V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTypical Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 450mV\/kPa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Conditioning\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Calibrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Compensation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePackage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-Terminal Through-Hole Sensor Package\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePin 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVout\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePin 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGND\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePin 3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePins 4, 5, 6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eN\/C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Medium\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry Air\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eApplications \/ Use Cases\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDifferential air-pressure measurement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAirflow monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHVAC monitoring projects\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFilter pressure-drop monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePneumatic control systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-pressure instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-pressure data logging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEmbedded pressure monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRobotics and automation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLaboratory measurement projects\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMicrocontroller-based pressure sensing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEducational electronics projects\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe MPX5010DP provides an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eanalog voltage output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so it can be used with microcontrollers, ADC modules, data-acquisition systems, and development boards that support a compatible analog input.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt may be used with platforms such as Arduino and other microcontroller systems, but it is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot Arduino-specific\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the output can approach the sensor supply voltage, users should verify the maximum ADC input voltage of the selected controller. A 3.3V microcontroller ADC should not automatically be connected directly to a higher-voltage sensor output without checking the electrical limits and using appropriate signal conditioning where required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe sensor is primarily characterized for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edry air\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Compatibility with liquids, corrosive gases, or other media should not be assumed without appropriate technical verification.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePackage Contents\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e1 × MPX5010DP Differential Pressure Sensor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eTubing, development boards, cables, connectors, and other accessories are not included unless specifically stated with the product.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBuy in Pakistan\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBuy the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMPX5010DP pressure sensor in Pakistan\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from Chip.pk for differential air-pressure measurement, low-pressure monitoring, embedded electronics, automation, and instrumentation projects.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0-10kPa measuring range, dual pressure ports, calibrated analog output, and integrated signal conditioning\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e make it suitable for applications where small pressure differences need to be monitored electronically.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1. What is the MPX5010DP pressure sensor?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe MPX5010DP is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0–10kPa differential pressure sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with two pressure ports and a conditioned analog voltage output for measuring small pressure differences.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2. What pressure range does the MPX5010DP measure?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIt is designed for a differential pressure range of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0 to 10kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3. Is the MPX5010DP an absolute or differential pressure sensor?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIt is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edifferential pressure sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It measures the pressure difference between its two pressure ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e4. What supply voltage does the MPX5010DP require?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe sensor is designed for a nominal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5V supply\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a specified supply range of approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4.75V to 5.25V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e5. What type of output does the MPX5010DP provide?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIt provides an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eanalog voltage output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e proportional to the measured differential pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e6. What is the typical output voltage range of the MPX5010DP?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eTypical output is approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.2V at 0kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and about \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4.7V at 10kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Actual output is subject to the manufacturer's transfer function and tolerances.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e7. Can I use the MPX5010DP with Arduino?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eYes. It can be interfaced with an Arduino or another microcontroller that has a suitable analog input. The ADC input-voltage limits of the controller must be respected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e8. Can I connect MPX5010DP directly to a 3.3V microcontroller?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eDo not assume direct compatibility. Because the sensor output can exceed 3.3V, the microcontroller's ADC maximum input voltage should be checked and suitable signal conditioning or voltage scaling used where required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e9. What do the two ports on the MPX5010DP do?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe two ports allow the sensor to compare pressure applied to each side and measure the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure difference between P1 and P2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e10. What are the MPX5010DP pin connections?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePin 1 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVout\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, Pin 2 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGND\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and Pin 3 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Pins 4, 5, and 6 are not used for normal external connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e11. Can the MPX5010DP measure liquids?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe sensor is primarily characterized for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edry air\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Compatibility with liquids or other media should not be assumed without suitable technical verification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e12. What applications can use the MPX5010DP?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIt can be used for airflow monitoring, filter pressure-drop measurement, pneumatic systems, HVAC projects, low-pressure instrumentation, automation, and microcontroller-based pressure monitoring.\u003c\/span\u003e\u003c\/p\u003e","brand":"Chip.pk","offers":[{"title":"Default Title","offer_id":67717368971549,"sku":null,"price":5800.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0998\/1060\/7389\/files\/MPX5010DPPressureSensorMacroShot.webp?v=1791557338","url":"https:\/\/www.chip.pk\/products\/mpx5010dp-differential-pressure-sensor","provider":"Chip.pk","version":"1.0","type":"link"}